{"id":538,"date":"2015-01-16T18:03:07","date_gmt":"2015-01-16T16:03:07","guid":{"rendered":"http:\/\/www.fultek.com.tr\/en\/?p=538"},"modified":"2026-04-27T13:15:54","modified_gmt":"2026-04-27T11:15:54","slug":"s7-1200-plc-profinet-protocol","status":"publish","type":"post","link":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/","title":{"rendered":"S7-1200 Plc Profinet Protocol"},"content":{"rendered":"\n<p>S7-1200 Profinet communication settings for WinTr SCADA.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Open the PLC project in the S7\u00a0TIA Portal software.<\/li>\n\n\n\n<li>Navigate to the PLC Properties. On the General Tab of the Properties page select Protection. Ensure that the &#8220;Full access (no protection)&#8221; radio button is selected. (The Siemens TCP\/IP Ethernet driver does not currently support the use of a password.) Check the &#8220;Permit access with Put\/Get communication from remote partner&#8221; check box.<\/li>\n\n\n\n<li>Ensure that any Data Blocks that need to be accessed have the &#8220;Accessible from HMI&#8221; box enabled.<\/li>\n\n\n\n<li>Ensure that any Data Blocks that need to be accessed have &#8220;Optimized block access&#8221;\u00a0disabled.<\/li>\n\n\n\n<li>Save these settings.<\/li>\n\n\n\n<li>Re-upload the project to the controller. It may also be necessary to cycle the power on the controller.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>S7-1200 Profinet communication settings for WinTr SCADA.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_swpsp_post_exclude":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[1],"tags":[199],"class_list":["post-538","post","type-post","status-publish","format-standard","hentry","category-scada","tag-wintr-scada"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>WinTr SCADA S7-1200 Profinet Communication Setup | Fultek<\/title>\n<meta name=\"description\" content=\"WinTr SCADA S7-1200 Profinet communication settings. Learn how to configure TIA Portal protection and enable Put\/Get access step-by-step.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Scada\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/\"},\"author\":{\"name\":\"Scada\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#\\\/schema\\\/person\\\/df45498fb898b0dd50c90cab08dfaedf\"},\"headline\":\"S7-1200 Plc Profinet Protocol\",\"datePublished\":\"2015-01-16T16:03:07+00:00\",\"dateModified\":\"2026-04-27T11:15:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/\"},\"wordCount\":130,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#organization\"},\"keywords\":[\"WinTr SCADA\"],\"articleSection\":[\"SCADA\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/\",\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/\",\"name\":\"WinTr SCADA S7-1200 Profinet Communication Setup | Fultek\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#website\"},\"datePublished\":\"2015-01-16T16:03:07+00:00\",\"dateModified\":\"2026-04-27T11:15:54+00:00\",\"description\":\"WinTr SCADA S7-1200 Profinet communication settings. Learn how to configure TIA Portal protection and enable Put\\\/Get access step-by-step.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/s7-1200-plc-profinet-protocol\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"S7-1200 Plc Profinet Protocol\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/\",\"name\":\"FULTEK | PLC | HMI | SCADA Software\",\"description\":\"PLC, HMI and SCADA Software \u2013 Industrial Automation Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#organization\",\"name\":\"FULTEK | PLC | HMI | SCADA Software\",\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/FultekLogo.png\",\"contentUrl\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/FultekLogo.png\",\"width\":290,\"height\":70,\"caption\":\"FULTEK | PLC | HMI | SCADA Software\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/#\\\/schema\\\/person\\\/df45498fb898b0dd50c90cab08dfaedf\",\"name\":\"Scada\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/74e267f7888087018e836ff4895a9b821489ce0a36abfbcd066f3b845c9c9522?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/74e267f7888087018e836ff4895a9b821489ce0a36abfbcd066f3b845c9c9522?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/74e267f7888087018e836ff4895a9b821489ce0a36abfbcd066f3b845c9c9522?s=96&d=mm&r=g\",\"caption\":\"Scada\"},\"sameAs\":[\"http:\\\/\\\/www.fultek.com.tr\\\/en\"],\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/en\\\/author\\\/salih\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"WinTr SCADA S7-1200 Profinet Communication Setup | Fultek","description":"WinTr SCADA S7-1200 Profinet communication settings. Learn how to configure TIA Portal protection and enable Put\/Get access step-by-step.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/","twitter_misc":{"Written by":"Scada","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/#article","isPartOf":{"@id":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/"},"author":{"name":"Scada","@id":"https:\/\/www.fultek.com.tr\/en\/#\/schema\/person\/df45498fb898b0dd50c90cab08dfaedf"},"headline":"S7-1200 Plc Profinet Protocol","datePublished":"2015-01-16T16:03:07+00:00","dateModified":"2026-04-27T11:15:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/"},"wordCount":130,"commentCount":0,"publisher":{"@id":"https:\/\/www.fultek.com.tr\/en\/#organization"},"keywords":["WinTr SCADA"],"articleSection":["SCADA"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/","url":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/","name":"WinTr SCADA S7-1200 Profinet Communication Setup | Fultek","isPartOf":{"@id":"https:\/\/www.fultek.com.tr\/en\/#website"},"datePublished":"2015-01-16T16:03:07+00:00","dateModified":"2026-04-27T11:15:54+00:00","description":"WinTr SCADA S7-1200 Profinet communication settings. Learn how to configure TIA Portal protection and enable Put\/Get access step-by-step.","breadcrumb":{"@id":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.fultek.com.tr\/en\/s7-1200-plc-profinet-protocol\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fultek.com.tr\/en\/"},{"@type":"ListItem","position":2,"name":"S7-1200 Plc Profinet Protocol"}]},{"@type":"WebSite","@id":"https:\/\/www.fultek.com.tr\/en\/#website","url":"https:\/\/www.fultek.com.tr\/en\/","name":"FULTEK | PLC | HMI | SCADA Software","description":"PLC, HMI and SCADA Software \u2013 Industrial Automation Solutions","publisher":{"@id":"https:\/\/www.fultek.com.tr\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fultek.com.tr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fultek.com.tr\/en\/#organization","name":"FULTEK | PLC | HMI | SCADA Software","url":"https:\/\/www.fultek.com.tr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fultek.com.tr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.fultek.com.tr\/en\/wp-content\/uploads\/2026\/05\/FultekLogo.png","contentUrl":"https:\/\/www.fultek.com.tr\/en\/wp-content\/uploads\/2026\/05\/FultekLogo.png","width":290,"height":70,"caption":"FULTEK | PLC | HMI | SCADA Software"},"image":{"@id":"https:\/\/www.fultek.com.tr\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.fultek.com.tr\/en\/#\/schema\/person\/df45498fb898b0dd50c90cab08dfaedf","name":"Scada","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/74e267f7888087018e836ff4895a9b821489ce0a36abfbcd066f3b845c9c9522?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/74e267f7888087018e836ff4895a9b821489ce0a36abfbcd066f3b845c9c9522?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/74e267f7888087018e836ff4895a9b821489ce0a36abfbcd066f3b845c9c9522?s=96&d=mm&r=g","caption":"Scada"},"sameAs":["http:\/\/www.fultek.com.tr\/en"],"url":"https:\/\/www.fultek.com.tr\/en\/author\/salih\/"}]}},"taxonomy_info":{"category":[{"value":1,"label":"SCADA"}],"post_tag":[{"value":199,"label":"WinTr SCADA"}]},"featured_image_src_large":false,"author_info":{"display_name":"Scada","author_link":"https:\/\/www.fultek.com.tr\/en\/author\/salih\/"},"comment_info":0,"category_info":[{"term_id":1,"name":"SCADA","slug":"scada","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"Scada Software Blog","parent":58,"count":11,"filter":"raw","cat_ID":1,"category_count":11,"category_description":"Scada Software Blog","cat_name":"SCADA","category_nicename":"scada","category_parent":58}],"tag_info":[{"term_id":199,"name":"WinTr SCADA","slug":"wintr-scada","term_group":0,"term_taxonomy_id":199,"taxonomy":"post_tag","description":"Technical tutorials for WinTr SCADA, including software installation, S7-1200 PLC communication settings, and fully redundant station configurations.","parent":0,"count":2,"filter":"raw"}],"_links":{"self":[{"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/posts\/538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/comments?post=538"}],"version-history":[{"count":2,"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/posts\/538\/revisions"}],"predecessor-version":[{"id":2408,"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/posts\/538\/revisions\/2408"}],"wp:attachment":[{"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/media?parent=538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/categories?post=538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fultek.com.tr\/en\/wp-json\/wp\/v2\/tags?post=538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}