{"id":212,"date":"2013-03-09T16:32:09","date_gmt":"2013-03-09T14:32:09","guid":{"rendered":"http:\/\/wintrscada.com\/?p=212"},"modified":"2021-12-18T13:30:53","modified_gmt":"2021-12-18T11:30:53","slug":"scada-performansi","status":"publish","type":"post","link":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/","title":{"rendered":"Scada Performans\u0131"},"content":{"rendered":"<p><a title=\"Scada\" href=\"http:\/\/www.fultek.com.tr\/programlar\/scada\/\">Scada<\/a> performans\u0131n\u0131 etkileyen fakt\u00f6rler a\u00e7\u0131klamaya \u00e7al\u0131\u015f\u0131cam. WinTr scada program\u0131 di\u011fer scadalardan farkl\u0131 olarak bir \u00e7ok se\u00e7ene\u011fi kullan\u0131c\u0131n\u0131n eri\u015fimine sunar. Bu avantaj dikkatsiz kullan\u0131c\u0131lar\u0131n elinde dez avantaj haline geldi\u011fi i\u00e7in bu yaz\u0131y\u0131 haz\u0131rlamak zorunda kald\u0131m. \u00d6ncelikle yapt\u0131\u011f\u0131n\u0131z scada projesinin bilgisayar kapasitesinin ne kadar\u0131n\u0131 kulland\u0131\u011f\u0131n\u0131 s\u00fcrekli kontrol etmelisiniz. Windows ara\u00e7 \u00e7ubu\u011fu \u00fczerinde sa\u011f k\u0131lik yaparak veya ctrl+alt+del tu\u015flar\u0131na birlikte basarak g\u00f6rev y\u00f6neticisini \u00e7al\u0131\u015ft\u0131r\u0131n. Performans k\u0131sm\u0131nda cpu ve ram kullan\u0131m\u0131n\u0131 g\u00f6zlemleyin. Bazen ba\u015fka programlarda performans\u0131 t\u00fcketebilir. Daha detayl\u0131 bir inceleme i\u00e7in i\u015flemler sayfas\u0131na bakabilirsiniz. Bu sayfada WinTr.exe ve Sqlserver.exe cpu ve ram kullan\u0131m\u0131n\u0131 inceleyin.<\/p>\n<p>Scada projesine ba\u011fl\u0131 olarak cpu kullan\u0131m\u0131 % 5\u2032i ge\u00e7mez. E\u011fer \u00e7ok b\u00fcy\u00fck projeler yap\u0131yorsan\u0131z ve webserver \u00f6zelli\u011fi kullan\u0131l\u0131yorsa %20\u2032ye kadar \u00e7\u0131kabilir. Ancak %20\u2032den daha fazla y\u00fckselmesi program\u0131n sa\u011fl\u0131kl\u0131 \u00e7al\u0131\u015fmayaca\u011f\u0131 anlam\u0131na gelir. Performans\u0131 olumzus etkileyen sebebleri ve \u00e7\u00f6z\u00fcmlerini a\u015fa\u011f\u0131da a\u00e7\u0131klad\u0131m.<\/p>\n<p>&#8211; <a title=\"Plc\" href=\"http:\/\/www.fultek.com.tr\/programlar\/speed-plc\/\">Plc<\/a> de\u011fi\u015fkenlerinin daha h\u0131zl\u0131 okunmas\u0131n\u0131 sa\u011flamak i\u00e7in scada projesinde g\u00f6r\u00fclen her de\u011fer bilin\u00e7sizce d\u00fc\u015f\u00fcr\u00fcl\u00fcr. B\u00f6ylece takip eden maddelerde a\u00e7\u0131klayaca\u011f\u0131m problemler ortaya \u00e7\u0131kar. Oysa plc ile ileti\u015fim h\u0131z\u0131 yaln\u0131zca connection manager b\u00f6l\u00fcm\u00fcnde ayarlan\u0131r. \u0130leti\u015fim h\u0131z\u0131n\u0131 etkileyen 3 fakt\u00f6r vard\u0131r. 1.poke zaman\u0131n\u0131n uzun olu\u015fu, 2.timeout s\u00fcresinin uzun olu\u015fu ve en \u00f6nemlisi tag adreslerinin ard\u0131\u015f\u0131k olmamas\u0131. Her ileti\u015fim protokol\u00fcn\u00fcn yard\u0131m sayfas\u0131n\u0131n en alt\u0131nda ard\u0131\u015f\u0131k adres girilmesinin \u00f6nemi ayr\u0131nt\u0131l\u0131 olarak anlat\u0131lmaktad\u0131r. Maalesef help sayfalar\u0131n\u0131 okuyan programc\u0131 ile kar\u015f\u0131la\u015fmad\u0131k. \u00d6zellikle bu b\u00f6l\u00fcm\u00fc okumayan kullan\u0131c\u0131lar, projeyi tamamlad\u0131ktan sonra plc program\u0131n\u0131 de\u011fi\u015ftirmek zorunda kalacaklard\u0131r. Testlerimizde bir plc ile 10000 Tag\u2019\u0131n de\u011fer de\u011fi\u015fimi her saniye okunabilmi\u015ftir. Bu h\u0131z tamamen konfig\u00fcrasyona ve plc ileti\u015fim h\u0131z\u0131na ba\u015fl\u0131d\u0131r.<\/p>\n<p>&#8211; Tag de\u011fer de\u011fi\u015fimini daha h\u0131zl\u0131 g\u00f6rmek i\u00e7in veya bilin\u00e7sizce Screen refresh zaman\u0131 \u00e7ok d\u00fc\u015f\u00fcr\u00fcl\u00fcyor. Baz\u0131 kullan\u0131c\u0131lar bunun ne i\u015fe yarad\u0131\u011f\u0131n\u0131 dahi bilmeden bu s\u00fcreyi alt limit olan 10 milisaniyeye kadar d\u00fc\u015f\u00fcr\u00fcyor. Oysa Tag de\u011fer de\u011fi\u015fimleri scada sayfalar\u0131na interrupt olarak ba\u011fl\u0131d\u0131r ve connection manager b\u00f6l\u00fcm\u00fcnde okunan tag de\u011feri anl\u0131k olarak sayfada g\u00f6sterilir. Daha h\u0131zl\u0131 tag de\u011fi\u015fimlerinin g\u00f6sterimi ilk maddede anlat\u0131lm\u0131\u015ft\u0131r. Screen refresh zaman\u0131 hakk\u0131nda daha fazla bilgiyi Screen properties help sayfas\u0131nda bulabilirsiniz.<\/p>\n<p>&#8211; Sql server kay\u0131t zaman\u0131 alt limit olan 10 milisaniyeye kadar azalt\u0131l\u0131yor. Scada projesi ilk olu\u015fturuldu\u011funda bu s\u00fcre 1000 mili saniyedir. Scada projeleri i\u00e7in \u00e7ok k\u0131sa bir s\u00fcredir. Normal olarak bu s\u00fcre 10 saniye yani 10000 mili saniye olmas\u0131 yeterlidir. Ancak k\u00fc\u00e7\u00fck projelerde 1000 mili saniye olmas\u0131nda bir sak\u0131nca yoktur. Database\u2019e yap\u0131lan kay\u0131tlar\u0131n periyotu Control panelinde Sql server sekmesinden ayarlan\u0131labilir. Database\u2019e kaydetti\u011finiz Tag say\u0131s\u0131na g\u00f6re bu zaman\u0131 ayarlamal\u0131s\u0131n\u0131z. Di\u011fer scada programlar\u0131 historical tag say\u0131s\u0131n\u0131 ayr\u0131ca satmaktad\u0131r. Baz\u0131lar\u0131nda en y\u00fcksek say\u0131 ise 250 tag\u2019d\u0131r. Baz\u0131 kullan\u0131c\u0131lar t\u00fcm tag\u2019lar\u0131 historical yap\u0131p (ne i\u015fe yarad\u0131\u011f\u0131n\u0131 ise bilmeden) database\u2019e kaydetmek istiyor. \u0130htiyac\u0131n\u0131z oldu\u011fu kadar de\u011fi\u015fkeni ihtiyac\u0131n\u0131z oldu\u011fu periyotta kaydetmelisiniz. E\u011fer \u00e7ok fazla kay\u0131t yapmak istiyorsan\u0131z, database\u2019i ba\u015fka bir bilgisayara ta\u015f\u0131yabilirsiniz.<\/p>\n<p>&#8211; Tek scada sayfas\u0131 i\u00e7ersinde bir \u00e7ok scada sayfas\u0131 \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131. WinTr haricinde hi\u00e7bir scada program\u0131nda olmayan Tabcontrol nesnesi buna imkan verir. Ancak bu \u015fekilde kullan\u0131m scada performans\u0131n\u0131 olumsuz etkileyecektir. Baz\u0131 kullan\u0131c\u0131lar bir tane scada sayfas\u0131 yap\u0131p sayfay\u0131 kaplayan tab control nesnesi i\u00e7ersine t\u00fcm scada sayfalar\u0131n\u0131 olu\u015fturuyor. B\u00f6ylece bir sayfa i\u00e7ersinde onlarca sayfa olu\u015fturulmu\u015f oluyor. Bir de bu sayfay\u0131 web server\u2019da kulland\u0131m\u0131 bir anda 20\u2032den fazla monit\u00f6r\u00fc olan bir bilgisayar haline geliyor. Oysa tab control nesnesi k\u00fc\u00e7\u00fck opsiyonlar olu\u015fturmak i\u00e7in kullan\u0131lmal\u0131d\u0131r. Tabcontrol help sayfas\u0131nda konu a\u00e7\u0131klanm\u0131\u015ft\u0131r.<\/p>\n<p>&#8211; \u00c7ok b\u00fcy\u00fck sayfay\u0131 tamamen kaplayan grafikler kullan\u0131ld\u0131\u011f\u0131nda screen refresh s\u00fcresi art\u0131r\u0131lmal\u0131d\u0131r. Grafik de g\u00f6sterilen zaman dilimi b\u00fcy\u00fck oldu\u011funda grafi\u011fin ekrandaki boyutuda b\u00fcy\u00fck ise performans olumsuz etkilenecektir. Bilgisayar\u0131n ekran kart\u0131 payla\u015f\u0131lan memory kullan\u0131yorsa bu problem daha ciddi olacakt\u0131r. Screen refresh s\u00fcresini art\u0131rarak performans\u0131 kontrol alt\u0131nda tutabilirsiniz.<\/p>\n<p>&#8211; Rapor \u00e7\u0131lg\u0131nl\u0131\u011f\u0131. Baz\u0131 m\u00fc\u015fteriler anlams\u0131z raporlar talep edebilir. \u00d6rne\u011fin bir ay boyunca her saniye kaydedilen bir de\u011feri rapor olarak almak isterler. Oysa rapor kaydedilmi\u015f verilerde belli durumlar\u0131 \u00f6zetlemek olmal\u0131d\u0131r. \u00d6rne\u011fin: x tarih ile y tarih aras\u0131nda tag de\u011feri \u015funu ge\u00e7enler bundan az olanlar gibi. Database\u2019in belirtilen tarihlerindeki verinin tamam\u0131n\u0131 al\u0131p sonra bu verinin i\u00e7inde s\u0131n\u0131rd\u0131\u015f\u0131 olan de\u011ferleri g\u00f6zle aray\u0131p bulmak bence \u00e7ok anlams\u0131z. Yinede b\u00f6yle veri al\u0131nabilir. Bu \u015fekilde \u00e7ok b\u00fcy\u00fck raporlar alacaksan\u0131z. Rapor alma ekran\u0131n\u0131 ayr\u0131 bir scada projesi olarak olu\u015fturmal\u0131s\u0131n\u0131z. Ayn\u0131 bilgisayarda iki adet scada projesi \u00e7al\u0131\u015ft\u0131r\u0131p birincisi normal \u00e7al\u0131\u015fma ikincisi rapor alma projesi olmal\u0131d\u0131r. B\u00f6ylece rapor alma i\u015flemi s\u0131ras\u0131nda birinci scada normal i\u015flemlerini aksatmadan yapabilecektir.<\/p>\n<p>Scada performan\u0131s\u0131n\u0131 etkileyen sebepleri anlatmaya \u00e7al\u0131\u015ft\u0131m. Yaz\u0131m\u0131n ba\u015f\u0131nda belirti\u011fim gibi bir \u00e7ok scada program\u0131 baz\u0131 \u00f6zellikleri kullan\u0131c\u0131n\u0131n de\u011fi\u015ftirmesine izin vermez. <a title=\"Otomasyon\" href=\"http:\/\/www.fultek.com.tr\/\">Otomasyon<\/a> uygulamalar\u0131m\u0131zda bu k\u0131s\u0131tlamadan dolay\u0131 ya\u015fad\u0131\u011f\u0131m\u0131z s\u0131k\u0131nt\u0131lar sebebi ile WinTr\u2019de her t\u00fcrl\u00fc imkan\u0131 kullan\u0131c\u0131ya tan\u0131d\u0131k. Bu seferde dikkatsiz ve yard\u0131m sayfalar\u0131n\u0131 okumayan kullan\u0131c\u0131lar scada program\u0131n\u0131 kitleyecek, performans\u0131n\u0131 d\u00fc\u015f\u00fcrecek i\u015flemler yap\u0131yor. Nihayi kullan\u0131c\u0131 ise problemin scada program\u0131ndan kaynakland\u0131\u011f\u0131n\u0131 d\u00fc\u015f\u00fcn\u00fcyor. Aylar sonra bir \u015fekilde konudan haberimiz olup hemen d\u00fczeltiyoruz. Ancak haberimiz olmayan problemli scada uygulamalar\u0131n\u0131n olmas\u0131ndan endi\u015fe ediyoruz. E\u011fer WinTr ile yap\u0131lm\u0131\u015f bir tane sa\u011fl\u0131ks\u0131z sistem varsa l\u00fctfen bizi aray\u0131n. Teamviewer ile online olarak derhal probleminiz giderelim. 2009 y\u0131l\u0131ndan itibaren sat\u0131\u015f\u0131n\u0131 yapt\u0131\u011f\u0131m\u0131z WinTr scada program\u0131 hakk\u0131nda tek olumsuz yaz\u0131n\u0131n internet ortam\u0131nda bulunmamas\u0131n\u0131n tek sebebi, \u00fcretti\u011fimiz programa sonuna kadar sahip \u00e7\u0131kmam\u0131zd\u0131r.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Scada performans\u0131n\u0131 etkileyen fakt\u00f6rler a\u00e7\u0131klamaya \u00e7al\u0131\u015f\u0131cam. WinTr scada program\u0131 di\u011fer scadalardan farkl\u0131 olarak bir \u00e7ok se\u00e7ene\u011fi kullan\u0131c\u0131n\u0131n eri\u015fimine sunar. Bu avantaj dikkatsiz kullan\u0131c\u0131lar\u0131n elinde dez avantaj haline geldi\u011fi i\u00e7in bu yaz\u0131y\u0131 haz\u0131rlamak zorunda kald\u0131m. \u00d6ncelikle yapt\u0131\u011f\u0131n\u0131z scada projesinin bilgisayar kapasitesinin ne kadar\u0131n\u0131 kulland\u0131\u011f\u0131n\u0131 s\u00fcrekli kontrol etmelisiniz. Windows ara\u00e7 \u00e7ubu\u011fu \u00fczerinde sa\u011f k\u0131lik yaparak veya ctrl+alt+del [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_swpsp_post_exclude":false,"footnotes":""},"categories":[1],"tags":[133],"class_list":["post-212","post","type-post","status-publish","format-standard","hentry","category-scada-genel","tag-scada-performansini-artiralim"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Scada Performans\u0131 - SCADA E\u011fitim Sitesi<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\" \/>\n\t<meta name=\"twitter:data1\" content=\"Salih\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/\"},\"author\":{\"name\":\"Salih\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/#\\\/schema\\\/person\\\/b439f08807fdc9e273a233976c5eb1be\"},\"headline\":\"Scada Performans\u0131\",\"datePublished\":\"2013-03-09T14:32:09+00:00\",\"dateModified\":\"2021-12-18T11:30:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/\"},\"wordCount\":1180,\"commentCount\":1,\"keywords\":[\"Scada Performans\u0131n\u0131 Art\u0131ral\u0131m\"],\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/\",\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/\",\"name\":\"Scada Performans\u0131 - SCADA E\u011fitim Sitesi\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/#website\"},\"datePublished\":\"2013-03-09T14:32:09+00:00\",\"dateModified\":\"2021-12-18T11:30:53+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/#\\\/schema\\\/person\\\/b439f08807fdc9e273a233976c5eb1be\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/2013\\\/03\\\/scada-performansi\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Scada Performans\u0131\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/#website\",\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/\",\"name\":\"SCADA E\u011fitim Sitesi\",\"description\":\"SCADA program\u0131 hakk\u0131nda bilmek istedikleriniz.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/#\\\/schema\\\/person\\\/b439f08807fdc9e273a233976c5eb1be\",\"name\":\"Salih\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/71953beeb6b97dd8eeecb5d9b86339eedb7662215ebdf0761d17ac26bc31f94b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/71953beeb6b97dd8eeecb5d9b86339eedb7662215ebdf0761d17ac26bc31f94b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/71953beeb6b97dd8eeecb5d9b86339eedb7662215ebdf0761d17ac26bc31f94b?s=96&d=mm&r=g\",\"caption\":\"Salih\"},\"sameAs\":[\"http:\\\/\\\/www.fultek.com.tr\"],\"url\":\"https:\\\/\\\/www.fultek.com.tr\\\/scada-yardim\\\/author\\\/salih\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Scada Performans\u0131 - SCADA E\u011fitim Sitesi","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/","twitter_misc":{"Yazan:":"Salih","Tahmini okuma s\u00fcresi":"6 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/#article","isPartOf":{"@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/"},"author":{"name":"Salih","@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/#\/schema\/person\/b439f08807fdc9e273a233976c5eb1be"},"headline":"Scada Performans\u0131","datePublished":"2013-03-09T14:32:09+00:00","dateModified":"2021-12-18T11:30:53+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/"},"wordCount":1180,"commentCount":1,"keywords":["Scada Performans\u0131n\u0131 Art\u0131ral\u0131m"],"inLanguage":"tr","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/","url":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/","name":"Scada Performans\u0131 - SCADA E\u011fitim Sitesi","isPartOf":{"@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/#website"},"datePublished":"2013-03-09T14:32:09+00:00","dateModified":"2021-12-18T11:30:53+00:00","author":{"@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/#\/schema\/person\/b439f08807fdc9e273a233976c5eb1be"},"breadcrumb":{"@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/2013\/03\/scada-performansi\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fultek.com.tr\/scada-yardim\/"},{"@type":"ListItem","position":2,"name":"Scada Performans\u0131"}]},{"@type":"WebSite","@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/#website","url":"https:\/\/www.fultek.com.tr\/scada-yardim\/","name":"SCADA E\u011fitim Sitesi","description":"SCADA program\u0131 hakk\u0131nda bilmek istedikleriniz.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fultek.com.tr\/scada-yardim\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Person","@id":"https:\/\/www.fultek.com.tr\/scada-yardim\/#\/schema\/person\/b439f08807fdc9e273a233976c5eb1be","name":"Salih","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/secure.gravatar.com\/avatar\/71953beeb6b97dd8eeecb5d9b86339eedb7662215ebdf0761d17ac26bc31f94b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/71953beeb6b97dd8eeecb5d9b86339eedb7662215ebdf0761d17ac26bc31f94b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/71953beeb6b97dd8eeecb5d9b86339eedb7662215ebdf0761d17ac26bc31f94b?s=96&d=mm&r=g","caption":"Salih"},"sameAs":["http:\/\/www.fultek.com.tr"],"url":"https:\/\/www.fultek.com.tr\/scada-yardim\/author\/salih\/"}]}},"_links":{"self":[{"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/posts\/212","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/comments?post=212"}],"version-history":[{"count":2,"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/posts\/212\/revisions"}],"predecessor-version":[{"id":1065,"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/posts\/212\/revisions\/1065"}],"wp:attachment":[{"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/media?parent=212"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/categories?post=212"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fultek.com.tr\/scada-yardim\/wp-json\/wp\/v2\/tags?post=212"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}